(1) Rated current (resistive):
KSD306: 60A
A. Breaking type
Full pole disconnection
B. Resistance between terminals
Below 50mW (digital milliohm millivoltmeter, DC10V, 1A)
(2) Insulation resistance
Use a DC500V insulation resistance meter with a rated voltage of DC500V to measure if it is greater than 100MW.
Electrical strength
The voltage withstand test between charged metal parts and non charged metal parts can withstand a 2000 V 50 Hz AC voltage close to a sine wave for one minute without breakdown or flashover
(3) Temperature characteristic type
Manual reset and auto reset
A. Maximum operating temperature
KSD306:150°C
B. Heat resistant temperature Tmax: 185 ° C
(4) Safety certification:
CQC,VDE,,ROHS
(5) Installation and usage instructions:
1. Grounding method: connect the metal cover of the temperature controller to the grounded metal parts of the equipment.
The temperature controller should work in a general indoor environment where the relative humidity of the air is not greater than 90% and there is no corrosive gas, combustible gas, and conductive dust.
When using contact temperature sensing for the temperature controller, the cover should be tightly attached to the heating part of the controlled appliance, and the temperature sensing surface of the cover should be coated with thermal conductive silicone grease or other thermal conductive media with similar performance.
4. Do not collapse or deform the top of the cover to avoid changing the operating temperature or affecting other performance.
5. Do not allow liquid to seep into the interior of the thermostat! The shell must avoid being subjected to excessive force to prevent cracks; The housing should be kept clean to prevent contamination by conductive substances, so as to avoid short circuit breakdown due to reduced insulation performance.
6. Do not bend the wiring terminals during use, otherwise the reliability of electrical connections will be affected.